4000 Series
A
new Generation of Engines
 |
4006
- 6 cylinder in-line water cooled diesel engine developing power
261-952 (Net) |
 |
4008
- 8 cylinder in-line water cooled diesel engine developing power
703-1274 bhp (Net) |
 |
4012
- 12 cylinder 60 degree Vee form water cooled diesel engine
developing power 924-1853 bhp (Net) |
 |
4016
- 16 cylinder 60 degree Vee form water cooled diesel engine
developing power 1440-2520 bhp (Net) |
Technical Data
Turbocharged, four stroke, premium specification water cooled diesel
engines. Individual models are specified with either radiator or
heat exchanger cooling for use in conjunction with remote radiators or
cooling towers.
| Bore
160mm |
| Stroke
190mm |
| Compression ratio
13.6:1 |
Rotation
Anti-clockwise
(When viewed from the flywheel end) |
| |
4006 |
4008 |
4012 |
4016 |
Total swept volume
(Litres) |
22.92 |
30.56 |
45.84 |
61.12 |
Sump oil capacity
(Litres) |
113.4 |
154.0 |
159.0 |
214.0 |
| Governing
To ISO 3046/4 A1 |
Fuel
Specification BS 2869 1988 Class A1 +
A2 or
ASTM D975 No. 2D or equivalent |
Standard equipment
| |
4006 |
4008 |
4012 |
4016 |
| Base Engine |
* |
* |
* |
* |
| Fuel Injection System, hand control
stop control, fuel lift pump and primer pump |
* |
* |
* |
* |
| Electronic Govenor |
* |
* |
* |
* |
| Medium Duty Air Cleaners - paper
elements |
* |
* |
* |
* |
| 24 Volt electrical equipment comprising
motor, battery charging alternator with low voltage control unit |
* |
* |
* |
* |
| SAE Flywheel and Housing (size
dependent on model) |
* |
* |
* |
* |
| Turbochargers |
+ |
+ |
+ |
+ |
| Vertical Exhaust Outlets |
+ |
+ |
+ |
+ |
| Fuel Oil Filter and Water Separator |
* |
* |
* |
* |
| Lubricating Oil Filters |
* |
* |
* |
* |
| Engine Jacket - Water Oil
Cooler/Temperature Stabiliser |
* |
* |
* |
* |
| Thermostats |
* |
* |
* |
* |
| Water Pumps |
* |
* |
* |
* |
| Free End Crankshaft Pulley |
+ |
+ |
+ |
+ |
| Crank Case Doors |
* |
* |
* |
* |
| Air to Water Charge Cooler using jacket
water |
+ |
+ |
+ |
+ |
| Torsional vibration damper to suit most
applications |
* |
* |
* |
* |
Engine protection pack for customer to
wire as necessary and comprising
a) 24 Volt stop solenoid energised to run
b)Low oil pressure/high water temperatures switch |
* |
* |
* |
* |
| Overspeed Switch with Magnetic Pick-up |
* |
* |
* |
* |
| Induction Air Shut-Off Valves |
|
|
* |
* |
| Engine feet |
* |
* |
* |
* |
| Perkins Engine User's Manuals |
* |
* |
* |
* |
Optional equipment
| |
4006 |
4008 |
4012 |
4016 |
Temperature Radiator (38 degree
Celsius) with Charge Air Cooler Matrix
(including water pipes, clips & hoses, fan, fan guards &
belts) |
|
|
|
o |
Tropical Radiator (52 degree Celsius)
with Charge Air Cooler Matrix
(including water pipes, clips & hoses, fan, fan guards &
belts) |
o |
o |
o |
o |
| Heavy Duty Air Cleaners - paper element
with pre-cleaner |
o |
o |
o |
o |
| Changeover Lubrication Oil Filter |
o |
o |
o |
o |
| Changeover Fuel Oil Filter |
o |
o |
o |
o |
| Immersion Heater with thermostat |
o |
o |
o |
o |
| Water pipes, clips & hoses for
radiator |
o |
o |
o |
o |
NB This list is not exhaustive,
further options may be available to meet particular applications on
enquiry to Perkins Sales Department
Notes * Standard Equipment + Standard Equipment according to